News
Articles
Case Histories
Tank Calculators
Buyer's Guide
Career Center
August 2008
August Card Deck
Industry Links
July 2008
Arsenic
Decentralized Wastewater
Filtration
Flow Measurement
Headworks
Membrane Technology
Pumps
Ultraviolet Disinfection
Click here for a subscription to
Water & Wastes Digest
Give us your feedback on our site.
Change your subscription info
Subscribe to our
WQP/WWD Executive NewsSummary e-Newsletter.
[ Flow Measurement Menu ]
Go with the Flow   Water & Wastes Digest February 2008   By James Panek
Flowmeter technology helps storm water management professionals accurately measure notoriously variable flows
PDF Version
Improving Water Disinfection Process Efficiency   Water & Wastes Digest July 2007   By Tristan J. Williams
Addressing the challenges associated with metering chlorine gas at a water treatment plant
PDF Version
Today, Tomorrow & Two Generations Ahead   Water & Wastes Digest January 2007   By Steve Werblow
Lower Colorado River Authority data delivers on-the-spot forecasts and 80-year projections
Flowmeters Defined   Water & Wastes Digest August 2006   David W. Spitzer
Vortex shedding, Coanda effect and vortex precession fluidic flowmeters
Online Monitoring Assures Pump Station Reliability, Saves Money   Water & Wastes Digest July 2005   By Ed Weaver
Because the online monitor of the central host sits beside the SCADA host at the TRWD Control Center, SCADA operators who control the pumps can monitor the status equipment, as well.
Going with the Flow   Water & Wastes Digest February 2005   By Brian Roughan
Appomattox, Va. River Water Authority recently installed an electromagnetic flowmeter in their fluoride feed line to measure instantaneous and total flow
How Does Pump Suction Limit the Flow?   Pump Source April 2003
One of the claimed advantages of centrifugal pumps over positive displacement pumps is their ability to operate over a wide range of flow. Since a centrifugal pump operates at the intersection of a pump curve and a system curve, by varying the system curve the operating point of the pump easily is changed. The convenience and simplicity of such flow control by the discharge valve throttling comes at a price because a pump is forced to run either to the left or right of its best efficiency point (BEP). The flow must be limited on both sides of the BEP.
Assessing Leakage in Water Supply Networks Using Flowmeters   Water Engineering & Management March 2003   Richard Furness, PhD., CEng. and ISA Fellow
Flowmeter usage is diverse and central to the entire water cycle control within the industry. The metering process directly or indirectly influences resource management, process control, new works planning, distribution management, leakage detection, financial control and environmental issues.
PDF Version
At Work on Flow Metering Devices   Water Engineering & Management January 2003
Professional flow data analysis now is accomplished easilyby the city's own engineering staff utilizing data management and report generation software.
Meters - High-accuracy Stormwater, CSO Flow Monitoring   Water & Wastes Digest July 2002
Ultrasonic transit-time flowmeters can be used to good effect for meeting specific site monitoring and documentation requirements by providing highly accurate and continuous flowrate measurement during dry- and wet-weather conditions.
New Flow Fitting, Low Flow Sensor Designed to Handle High Viscosity Fluids   Water & Wastes Digest April 2002
Users needing to measure the flow of specialty chemicals, food additives, adhesives and other viscous fluids will find an ideal solution in two new positive displacement flow fitting/sensors now available from Burkert.
Insertable Electromagnetic Flowmeter Solves Difficult Piping Problem   Water & Wastes Digest April 2001
A difficult piping arrangement that included limited distance between the metering site and pipe fittings posed a dilemma for the engineering staff at a city of Frederick, Maryland, raw water pumping station.
PDF Version
At Work on Flow Measuring Devices   Water Engineering & Management January 2001
In the past, a pitot tube meter was used to profile the pipe and measure the flow at the two points. The valuable time required by divers to accomplish flow profiling on the gulf sea floor and less than satisfactory results led to a search for a better flowmeter.
PDF Version
Ultrasonic Flowmeters Provide Cost-effective Measurements   Water & Wastes Digest January 2000
If your wastewater plant is like most others, you are probably using several flowmeters to monitor the system. But as the cost of water rises, so does the cost of measurement. A comprehensive line of flowmeters is available from Panametrics in Waltham, Mass., to accurately and reliably measure many liquids.
Flow Metering Inserts Offer Safety, Economics, Accuracy to Wisconsin Environmental Lab   Water & Wastes Digest August 1998
Badger Laboratories & Engineering Co., Inc., located in Neenah, Wisc., is a full-service environmental lab offering engineering and field services in addition to laboratory analysis. Isco Flow Metering Inserts provide a quick and accurate means of measuring and recording flow in round sewer pipes.
Understanding and Solving Fracture Flow Problems   Water Engineering & Management September 1997   Dr. Thomas Doe
This article compares fracture flow with flow in more conventional porous systems and suggests solutions to fracture flow problems.
Verifying Open Channel Flowmeter Performance   Water & Wastes Digest May 1997   Larry Marsh
Literally billions of dollars in infrastructure decisions are based on the results from I & I studies using velocity area flowmeters. When thoroughly tested, most commercial flowmeters are shown to be inadequate for most wastewater flow measurement needs.
Velocity Flowmeter Aids Sanitary Wastewater Sewer System Evaluation Survey   Water Engineering & Management May 1997
The end of the sewer line for unincorporated Sedgwick County is the Kansas Coliseum. Home to two professional sports teams, the 10,000-seat events arena hosts concerts, exhibitions and livestock shows. A 25,000-seat outdoor amphitheater expansion is now being considered. In addition, a proposal is in effect for a nearby residential development.
Demystifying Doppler Flowmeters in Sewage Flow Measurement   Water Engineering & Management April 1996   Thomas J. Day
Doppler technology has advanced for flow monitoring sites that would have proved difficult to impossible to meausre just a few years ago.
Ultrasonic Technology Simplifies Flow and Level Measurement   Water Engineering & Management December 1994   Edited by Tracy Drake
A non-contact sensing instrument solved flow and level measuring problems

Advertise with us
Learn about our online marketing opportunities.
Home   |   Advertising   |   News Search   |   Articles   |   Buyer's Guide   |   Career Center   |   Case Histories   |   Top of Page